Close-up view of intricate beige lace fabric and sheer material, ideal for fashion and textile projects
ExplainersIndependently verified

What is 16 CFR 1610? The clothing flammability standard, Class 1, 2 and 3

By Zain·

Photo: https://kaboompics.com/ / Pexels

16 CFR 1610 is the U.S. flammability standard for clothing textiles. It sorts fabrics into three classes by burn speed and bans Class 3, the dangerously fast burners, from clothing. Class 1 does not mean flame resistant.

16 CFR 1610 is the federal flammability standard for clothing textiles. The Consumer Product Safety Commission calls it the General Wearing Apparel Standard. It tests how fast a fabric burns, assigns it to Class 1, 2 or 3, and says Class 3 fabrics, the ones that burn rapidly and intensely, are dangerously flammable and cannot be used in clothing. Most ordinary fabrics never need to be tested, and passing does not make a garment flame resistant.

What the standard covers

The rule's stated purpose is to reduce injury and loss of life from dangerously flammable clothing textiles by setting national test methods and ratings. It applies to "clothing and textiles intended to be used for clothing," according to 16 CFR 1610.1(b). A CPSC staff presentation from September 2015 describes it as dating from the 1950s and as keeping the most dangerously flammable textile products and garments out of the marketplace. (The deck says it was prepared by staff and was not reviewed or approved by the Commission, so we treat it as explanatory, not binding.) The standard applies to fabrics and to finished garments, according to the Commission's 1998 policy statement in the Federal Register.

Four things are excluded from the standard under 1610.1(c): hats, unless they form a covering for the neck, face or shoulders; gloves up to 14 inches long that are not attached to another garment; footwear, unless it is hosiery or attached to another garment; and interlining fabrics used between an outer shell and an inner lining.

The three classes

The classes depend on burn time, and the dividing line depends on whether the fabric has a raised surface such as a pile, a nap or flocking. The eCFR text defines a raised surface as "an intentionally raised fiber or yarn surface, such as a pile, including flocked pile, nap, or tufting," and a plain surface as any fabric that does not have one.

| Class | Plain surface fabric | Raised surface fabric | |---|---|---| | 1 (normal) | burn time of 3.5 seconds or more | burn time over 7.0 seconds, or a surface flash with no base burn | | 2 (intermediate) | not used | burn time of 4.0 to 7.0 seconds with base burn | | 3 (rapid and intense) | burn time under 3.5 seconds | burn time under 4.0 seconds with base burn |

Class 1 is acceptable for clothing. Class 2 applies only to raised surface fabrics and may be used. Class 3 "shall not be used for clothing," in the rule's words. CPSC's staff deck labels Class 2 "use with caution." The deck prints its Class 1 plain-surface cutoff as above 3.5 seconds and the eCFR summary reads at least 3.5, so treat exactly 3.5 seconds as a boundary case and consult the rule text if you need it.

“a small number of textile products exhibit variability in the test results”

Consumer Product Safety Commission, Federal Register policy statement, August 11, 1998
Detailed close-up of assorted plaid and checkered fabrics, showcasing textile textures and patterns
Fabric swatches of the kind sorted by weight and surface under the standard. Photo: Tima Miroshnichenko / Pexels

How the test works

The specimen is 50 mm by 150 mm, mounted at a 45 degree angle. A flame is applied for one second and burn time is measured over 127 mm, about five inches. Fabrics are tested twice, once in their original state and once after refurbishing, meaning dry cleaning and then laundering. The final class is the more severe of the two results, under 1610.7(a). That second step matters: a fabric that passes new can fail after washing.

Which fabrics are exempt from testing

Under 1610.1(d), two groups need no testing. Plain surface fabrics weighing 2.6 oz per square yard or more are exempt whatever their fiber. Plain or raised surface fabrics made entirely of acrylic, modacrylic, nylon, olefin, polyester or wool are exempt whatever their weight. In practice, that is why a heavy cotton twill or a polyester jacket never gets a burn test.

Which fabrics fail

The CPSC staff deck lists these as common noncomplying fabrics:

  • sheer 100% rayon skirts and scarves
  • sheer 100% silk scarves
  • 100% rayon and rayon/nylon chenille sweaters
  • long animal hair sweaters
  • polyester/cotton and 100% cotton fleece garments
  • 100% cotton terry cloth robes

Rayon appears twice on that list. Our explainer on viscose and rayon fabric covers how the fiber is made.

Why a passing result is not a guarantee

The 1998 policy statement, written to guide manufacturers, importers, distributors and retailers on civil penalties, notes that "a small number of textile products exhibit variability in the test results." That means a single passing result may not show that a style will always pass. The same statement says CPSC considers whether a firm "had actual knowledge that its products violated the flammability requirements" when judging whether a violation was knowing.

So the standard keeps the worst-burning fabrics out of stores, and it is enforced against firms. It does not make a Class 1 sweater flame resistant, and it does not say a garment is safe near a candle or a stove.

What about children's clothing?

Children's sleepwear sits under separate rules, 16 CFR 1615 and 1616. Those are why pajamas for young children are either snug fitting or made of flame-resistant fabric. We explain that rule in why kids' pajamas are tight fitting. The General Wearing Apparel Standard covers other children's and adult clothing.

The position

16 CFR 1610 is a low bar that does its job: it removes the fastest-burning fabrics from the market. Shoppers should not expect a flammability tag on most clothes, because most are exempt, and should not confuse "passed" with "flame resistant." If you wear sheer, brushed or fuzzy knits, keep them away from open flame. If you sell them, confirm the fabric's class with a lab test after laundering.

Frequently asked questions

What is 16 CFR 1610?

The federal flammability standard for clothing textiles, called the General Wearing Apparel Standard. It tests burn speed, assigns Class 1, 2 or 3, and bars Class 3 fabrics from clothing.

What are Class 1, Class 2 and Class 3 fabrics?

Class 1 burns normally and is acceptable. Class 2 has intermediate flammability, applies only to raised surface fabrics and may be used. Class 3 burns rapidly and intensely and may not be used in clothing.

Does Class 1 mean flame resistant?

No. Class 1 means normal flammability under the test. The standard only screens out the most dangerous fabrics.

Which fabrics are exempt from 16 CFR 1610 testing?

Plain surface fabrics of 2.6 oz per square yard or more, and fabrics made entirely of acrylic, modacrylic, nylon, olefin, polyester or wool, under 1610.1(d).

Which clothes commonly fail the flammability standard?

CPSC staff list sheer 100% rayon skirts and scarves, sheer silk scarves, rayon chenille sweaters, long animal hair sweaters, cotton fleece and cotton terry robes as commonly noncomplying.

Does the standard cover children's sleepwear?

No. Children's sleepwear is covered by separate rules, 16 CFR 1615 and 1616.

Sources

What each one is, and whose it is.

  1. 1

    16 CFR Part 1610 Standard for the Flammability of Clothing Textiles, Electronic Code of Federal Regulations (November 13, 2026)

    DocumentationIndependent of the vendor
  2. 2

    Highlights of Apparel and Textile Requirements in the United States, U.S. Consumer Product Safety Commission staff (August 31, 2015)

    DocumentationIndependent of the vendor
  3. DocumentationIndependent of the vendor